Product Class
Handheld Pulse Oximeter
  NT1
  NT1A
  NT1B
Handheld Vital Signs Monitors
  NT1D Series
Vital Signs Monitors
  NT2A
  NT2C
Multiparameter Patient Monitors
  NT3A (10.4")
  NT3B (12.1")
  NT3C (10.4")
  NT3E (8.4")
  NT3F (7")
Central Monitoring System
  NTC2700
Monitoring Accessories
  SpO2
  NIBP Cuffs
  ECG Cables
  Temperature Sensors
>> Contact Us
400 Oyster Point Blvd.
Ste. 534
South San Francisco
CA 94080, USA
TEL: +1 650 5883980
FAX: +1 650 5883988
E-mail:
sales@solarismedtech.com
Product -- NT2C (CE Marked)
NT2C Portable Vital Signs Monitor
Product Description:

◆Bright, Easy-to-Read Large LED Display
◆Durable, Compact and Lightweight
◆Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
◆Bright, Easy-to-Read Large LED Display
◆Durable, Compact and Lightweight
◆Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
◆Audible/Visual Three Level Alarms with Alarm Volume Control
◆72-hour Data Memory Allowing On-screen data replay
◆Suitable for Adult, Pediatric and Neonate
◆Optional Internal Thermal Recorder


Product Features :

◆Performance Measurement Range:
SpO2: 0%-100%
Pulse Rate: 30bpm~250bpm

◆SpO2 Accuracy:
Adults, Pediatrics: 70%-100% ±2%
                    0%-69% unspecified
     Neonates:      70%-100% ±3%
                    0%-69% unspecified
◆Pulse Rate Accuracy
Adults, Pediatrics, Neonates: ±3%

◆ECG
ECG cable: 5 Lead ECG Cable
Lead selection:Ⅰ,Ⅱ, Ⅲ/ aVR,  aVL,  aVF/ V
Gain (mm/mV): 1/4, 1/2,1, 2, 4, Manual/Automatic
Sweep speed (mm c):  6.25, 12.5, 25, 50
Heart rate range: 30-300bpm
Heart rate accuracy:±1bpm or ±1 %
ST segment analysis (Diagnostic mode):
    a. ST range: -2.0mV-+2.0mV
    b. ST accuracy:±0.02mV
Monitoring mode: Diagnostic    0.05-100Hz
                               Monitoring     0.5-40 Hz
                               Operating      1.0-25 Hz

◆Non-Invasive Blood Pressure:
Measurement   type:  Adult, Pediatric, Neonatal
Measurement range:
Adult:            Systolic    40-270mmHg
                  Diastolic   20-200mmHg
                  Mean        30-220mmHg
Pediatric:        Systolic    40-180mmHg
                  Diastolic   15-160mmHg
                  Mean        20-170mmHg
Neonatal:         Systolic    30-140mmHg
                  Diastolic   15-100mmHg
                  Mean        20-115mmHg
Accuracy:  Meets ANSI/AAMI SP10-1992
Resolution: 1mmHg
Protection:  over pressure

◆Alarm
Audible/visual Alarms
Adjustable Alarm Limits

◆Temperature:
Measurement range: 25 ~ 45 ℃
Accuracy:  ± 0.2 ℃

◆Output:
RS-232 Serial Port for Digital Output
Nurse Call Function

◆Electrical Instrument:
Power Requirements: 100~240VAC, 50/60Hz, 40VA
Fuse Rating:        1.0A

◆Battery:
Internal Battery:   12V
Battery Capacity:     24 hours

◆Environment:
Operating:
Temperature: 5OC~40OC (41OF ~104OF)
Humidity:    10%~95%            
Transport/Storage:
Temperature: -20OC~70OC (-4OF ~158OF)
Humidity:    10%~95%

◆Physical Characteristics:
Dimensions:    264mm(W) x 95mm(H) x 172mm(D)
               10.39in(W) x 3.74in(H) x 6.77in(D)
Net Weight:      2.25kg/5 Ib

◆Compliance:
1. SpO2: ISO 9919: 2005(E)
2. Safety Standards:
    EN 60601-1: 1990+A1: 1993+A2: 1995+A13: 1996
3. Alarm: IEC60601-1-8: 2005
4. EMC: EN 60601-1-2: 2007, Group 1 Class A
5. Environment : WEEE (2002/96/EC)







 
   